How to Use JPRO Professional to Perform DPF Regeneration

How to Use JPRO Professional to Perform DPF Regeneration

JPRO Professional can support DPF Regeneration for Cummins,Detroit,International,MACK,Paccar,Volvo and more. So here Autonumen.com show you guide on how to use JPRO Professional to perform DPF Regen.

Preparations:

JPRO Professional Heavy Duty Diagnostic Software Download

Note:Please ensure you have followed all necessary safety precautions BEFORE performing a forced regen.

Procedures:

In the top left corner,vehicle health indicators may alert that you need to perform a DPF regen.

Click the “DPF Regen Needed” button

Then it will show the Aftertreatment Diagnostics screen.Notice in the top right,buttons indicate a needed OR inhibited regen.To initiate a DPF regen,simply click the “Start DPF Regen” button

Alternatively,click the “Aftertreatment Diagnostics” button from the toolbar will also launch the Aftertreatment screen

Additionally,you can access a DPF Regen from the Bi-Directional Test screen.Click the “Bi-Directional” button from the main toolbar.

Select the “DPF service Regen” test and click the “Start” button to launch the Aftertreatment screen

And for those who hold NextStep can access a DPF regen from the NextStep screen.

Click the “Bi-Directional” button on the right hand side.